Repository logo
Communities & Collections
All of DSpace
Formato del repositorio
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "RODRIGUEZ RODRIGUEZ, EDWAR SANTIAGO"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Item
    EVALUACION DEL COMPORTAMIENTO DE SISTEMAS ´ DE ALMACENAMIENTO POR BATERIAS BAJO LA INFLUENCIA DE FENOMENOS DE CALIDAD DE LA ´POTENCIA EN LA RED ELECTRICA
    (2024-09-09) RODRIGUEZ RODRIGUEZ, EDWAR SANTIAGO; MOYA DIAZ, DANIEL ALEJANDRO; GUERRERO GUERRERO, ANDRES FELIPE
    Este documento presentó el diseño de un sistema de almacenamiento de energía mediante baterías (BESS) con el propósito de mitigar los armónicos de corriente en la red eléctrica generados por cargas no lineales. Los armónicos, que consisten en frecuencias múltiplos de la señal eléctrica fundamental, pueden reducir la eficiencia energética, causar sobrecalentamiento en los equipos y provocar problemas de interferencia electromagnética. El sistema BESS se sincronizaba con los parámetros de tensión y frecuencia típicos de la red trifásica nacional. Para lograr la mitigación de armónicos en la red, inyecta corrientes en contrafase en el punto de conexión común (PCC) mediante una estrategia de control que genera comandos para modular el inversor con la técnica de modulación de espacio vectorial por ancho de pulso (SVPWM). La simulación de la topología implementada se realizaba en la extensión de Simulink en el entorno proporcionado por el software Matlab, donde se configura el sistema de almacenamiento con la estrategia de control implementada, conectándolo a la red eléctrica. En esta simulación, se evaluaban diversos escenarios de prueba para determinar el impacto de la capacidad nominal de la batería y los requisitos de carga en el sistema. Los resultados de los escenarios de prueba se exponían y analizaban, evaluando el desempeño del sistema BESS frente a variaciones en los requerimientos de carga y la capacidad nominal de la batería. En este contexto, cabe mencionar que el mejor caso de prueba logró una reducción del THD de 5.61%. Además, se destaca la capacidad del sistema para mantener un rendimiento estable incluso bajo condiciones de alta demanda, reduciendo la distorsión armónica al 12.24%. Abstract This document presented the design of a Battery Energy Storage System (BESS) aimed at mitigating current harmonics in the electrical grid generated by non-linear loads. Harmonics, which consist of multiples of the fundamental electrical signal's frequency, can reduce energy efficiency, cause equipment overheating, and lead to electromagnetic interference issues. The BESS system must synchronized with typical voltage and frequency parameters of the national three-phase grid. To achieve harmonic mitigation in the grid, it injects currents in anti-phase at the Point of Common Coupling (PCC) using a control strategy that generates commands to modulate the inverter with the Space Vector Pulse Width Modulation (SVPWM) technique. Simulation of the implemented topology was conducted using the Simulink extension within the Matlab software environment, configuring the storage system with the implemented control strategy and connecting it to the electrical grid. Various test scenarios were evaluated in this simulation to determine the impact of the battery's nominal capacity and load requirements on the system. The results of the test scenarios were presented and analyzed, assessing the BESS system's performance under varying load requirements and battery nominal capacity. In this context, it is worth mentioning that the best test case achieved a 5.61% reduction in Total Harmonic Distortion (THD). Furthermore, the system's capability to maintain stable performance, even under high-demand conditions, is highlighted, reducing harmonic distortion to 12.24%.

DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback

Línea gratuita: 018000180417 | e-mail: biblioclic@ucundinamarca.edu.co


Seccional Girardot: Carrera 19 No. 24-209 | (+571)8335071

Seccional Ubaté: Calle 6 No. 9-80 | (+571)8553055

Extensión Chía: Autopista Chía - Cajicá | Sector "El Cuarenta" | (+571)8281483 Ext. 418

Extensión Facatativá: Calle 14 con Avenida 15 | (+571)8920706

Extensión Soacha: Diagonal 9 No. 4B-85 | (+571)7219220

Extensión Zipaquirá: Carrera 7 No. 1-31 | (+571)8515792

Oficinas Bogotá D.C.: Carrera 20 No. 39-32 Teusaquillo | (+571)7448180

Notificaciones judiciales:


Dirección Jurídica (+571)8281483 Ext. 115 | e-mail: oficinajuridicaaunclic@ucundinamarca.edu.co

Política de Tratamiento de Datos Personales

© 2025 UCUNDINAMARCA Generación Siglo 21

Vigilada Mineducación

Reconocida por Resolución No. 19530, de Diciembre 30 de 1992 (MEN)

Oficina Asesora de Comunicaciones

Derechos reservados